What are causes of leakage of pneumatic ball valves?

When using pneumatic ball valves, there will be leakage problems. So, what are the causes of leakage of pneumatic ball valves? The following where the righteousness of the valve factory with you simply summed up the next.

What are causes of leakage of pneumatic ball valves?

1. Leakage between the right body and the left body. Trim the sealing surface, remove dirt, replace the gasket, and tighten the nut evenly and interspersed.

2. Packing leakage. Tighten gland bolts or replace packing (top packing 1, middle packing 2, bottom packing 1). Take care not to cut the edge during installation and tighten the gland bolt evenly.

3. Stem is not sensitive. Adjust the cover bolt, evenly adjust the joint nut or the thickened gasket to reduce the preload, be careful not to leak.

4. Seal leakage. Evenly and interspersed tighten the joint nut of the pivot body to increase the pre-tightening force, or adjust the sealing seat and gasket and clean the sealing groove.

5. When the ball valve can not be turned, do not cover the wrench assisted lever or other things hard pulling, this will damage the valve stem. If the operation of hard to analyze the reason, some of the valve closed by thermal expansion into open difficult, at the moment can be the gland bolt loose, to eliminate the stress of the valve stem and then open, packing is too tight, can be appropriately relax the packing.

6. Ball valves can only be fully open or fully closed, usually not allowed for conditioning and throttling. The ball valve with a wrench is fully open when the wrench is parallel to the channel and fully closed when turning 90°.

7. Seal leakage. Evenly and interspersed tighten the joint nut of the pivot body to increase the pre-tightening force, or exchange the sealing seat and gasket and clean the sealing groove.

Contact us

If possible, kindly suggest please your working industry/process, working pressure, working medium, etc. Given detailed request helps to gain better-matched customized solution. Thanks for your patience.

your request will be responsed within 3 hours, kindly pay attention to your email please.

News

vacuum pump in medical equipment application

Posted on Tue, 22 Jun 2021 07:12:55 +0000

PCB vacuum pressing vacuum unit

Posted on Mon, 21 Jun 2021 08:29:48 +0000

Screw Vacuum Pump Are In Vogue

Posted on Wed, 16 Jun 2021 09:11:03 +0000

37kw liquid ring vacuum pump

Posted on Thu, 10 Jun 2021 08:54:59 +0000

Hospital ultrasonic water ring vacuum pump

Posted on Wed, 09 Jun 2021 07:24:28 +0000

Oil-free dry screw vacuum pump solves environmental problems

Posted on Thu, 03 Jun 2021 07:23:09 +0000