Liquid ring vacuum pump for filter separator

New public a kind of liquid ring vacuum pump, gas water separator, including cylinder, cylinder is equipped with air inlet pipe, the exhaust pipe and return pipe, one end of the intake pipe tube in vitro, on the other side of the intake pipe and cross section along the barrel radial and cylinder are connected, the second damper cylinder body is equipped with the cone, the second baffle cone pointed toward the inlet pipe, the second baffle leave gaps between the cone and the inlet pipe of export; A conical first baffle is arranged on the inside of the cylinder and the upper part of the intake pipe. The cone of the first baffle is a network structure, and the cone tip of the first baffle is towards the top of the cylinder. Tube, intake pipe, exhaust pipe and return pipe are made of glass fiber reinforced plastic. The gas-water separator can separate water vapor twice, which greatly improves the separation efficiency. At the same time, extend the service life, reduce the maintenance, overhaul workload. Liquid ring vacuum pump for filter separator

In use, the following accessories can be installed according to the actual situation:

1, suction port vacuum check valve. To prevent backflow when vacuum pump/compressor stops, it is generally necessary to install vacuum check valve or pneumatic valve at the inlet of the pump.
2. Suction port vacuum gauge or pressure sensor. In order to observe the pressure of the suction port of the pump, a vacuum meter can be installed in the suction port of the pump. If the control action is required according to the suction pressure, the pressure sensor should be installed in the suction port of the pump.
3. Air inlet filter. If the system and pipeline may have foreign matter into the pump, should be installed in the pump suction mouth filter or mesh.
4. Overflow port of separator. Excess working fluid can be discharged from the gas-liquid separator.
5. Liquid supplement port of separator. If the working fluid is insufficient, the working fluid can be properly supplemented from the filling port.
6. Liquid level meter of separator. The liquid level in the separator can be observed. If automatic control of the liquid level is needed, the liquid level meter with signal output, automatic overflow or liquid replenishment device should be installed.
7. Pressure gauge for separator. If pressure may be generated in the separator, a pressure gauge should be installed on the separator.
8. Thermometer. If it is necessary to observe the inlet temperature of the working fluid, a thermometer should be installed in the working fluid pipeline.
9. Working fluid booster pump. If the working fluid supply of the pump is insufficient or the working pipeline resistance is large, the working fluid booster pump can be installed.
10, working fluid control valve. If the working fluid supply may be too large, a control valve should be installed in the working fluid line.
11. Cavitation protection pipeline. If the suction pressure of the vacuum pump is close to the saturated vapor pressure of the working fluid, a cavitation protection pipeline should be installed between the vacuum pump and the separator.
12. If it is used as a compressor, a balance pipe and corresponding valve accessories should be installed between the suction and exhaust pipes of the compressor.
13. Stop valve of suction pipe, exhaust pipe and working fluid pipe. If the liquid ring vacuum pump/compressor is designed to be used in parallel for multiple pumps, when the separator is Shared, a cut-off valve should be installed in the suction pipe, exhaust pipe and working fluid pipe.
14. Exhaust condenser. If it is necessary to collect or recycle condensable gas in the vent, a condenser can be installed in the vent of the gas-liquid separator.
15, if there are other special requirements, can install the appropriate accessories.

Notes for liquid ring vacuum pump equipment selection:

Liquid ring vacuum pump for filter separator

Because the selection of liquid ring vacuum pump/compressor needs to be calculated according to detailed working conditions, if our company is required to carry out design and selection, please be sure to provide detailed working conditions.

Liquid ring vacuum pump closed-circuit circulation system is made up of 2BV or 2BE series liquid ring vacuum pump, steam separator, heat exchanger and all kinds of pipeline accessories. Compared with a single liquid ring vacuum pump, it is more convenient to install. Because the working fluid can be recycled, the system greatly reduces the consumption of working fluid and the pollution to the environment, so it is toxic in the extracted gas, the extracted gas contains organic solvents and other occasions have obvious advantages. Liquid ring vacuum pump closed circulation system can be used in most applications.

Liquid ring vacuum pump closed-circuit circulation system working fluid can use a variety of media: water, methanol, ethanol, xylene, aniline, acetone and other organic solvents, transformer oil.

(The article comes from the Internet. If reprinting is not allowed, please contact our company to delete it.)

Contact us

If possible, kindly suggest please your working industry/process, working pressure, working medium, etc. Given detailed request helps to gain better-matched customized solution. Thanks for your patience.

your request will be responsed within 3 hours, kindly pay attention to your email please.

News

dry screw vacuum pump in wood processing industry

Posted on Tue, 01 Feb 2022 07:02:47 +0000

Explosion proof and high temperature resistant vacuum unit

Posted on Wed, 10 Nov 2021 07:30:11 +0000

vacuum pumps for chemical industry has high requirements

Posted on Mon, 08 Nov 2021 08:52:52 +0000

What are the applications of roots vacuum units in medicine?

Posted on Wed, 03 Nov 2021 07:57:18 +0000

The advantages of dry screw vacuum pumps make up for the disadvantages of oil-sealed vacuum pumps

Posted on Tue, 02 Nov 2021 09:05:35 +0000

dry vacuum pump for measures to avoid oil return

Posted on Thu, 28 Oct 2021 09:03:25 +0000