EVP CL Liquid Ring Vacuum Pump Feature

Posted on Fri, 21 Dec 2018 03:27:34 +0000

EVP CL Vacuum Pumps & Compressors iff air carries solid contaminants , vapor is to be reclaimed , and you want smooth operation . CL Pumps are single stage vacuum pumps ideal for demanding applications in extremely tough conditions. Heavy duty pumps, they are able to service a wide range of a...

+ Continue reading

The contrast between dry screw vacuum pump and rotary piston vacuum pump

Posted on Fri, 14 Dec 2018 02:35:30 +0000

Due to the space simulation device has a volume of the pumping container from thousand cubic meters to tens of thousands of cubic meters, the vacuum pressure changes from from tens of thousands of Pascal to several Pascal, and the pumped gas contains a large amount of water vapor or a part of nit...

+ Continue reading

Vacuum Pump in Vacuum Grouting Process

Posted on Fri, 14 Dec 2018 02:27:02 +0000

Vacuum grouting is a grouting process in which a vacuum pump is used to vacuum the outside of the plaster mold, or the reinforced plaster mold is placed in a vacuum chamber for negative pressure operation. Vacuum grouting reduces the formation time of the blank by increasing the pressure differen...

+ Continue reading

Liquid Ring Vacuum Pump for Evaporator

Posted on Thu, 06 Dec 2018 01:48:57 +0000

Vacuum evaporators are widely used in the evaporation and concentration of water or mailing solvent solutions in the pharmaceutical, food, chemical, light industry and other. It is especially suitable for heat sensitive materials (such as important production water, alcohol extract, antibiotic fe...

+ Continue reading

The difference between the three common vacuum flange specifications (CF, KF, ISO)

Posted on Wed, 21 Nov 2018 03:34:50 +0000

1, CF flange The English name for the CF flange is Conflat Flang. It is a flanged connection for ultra-high vacuum and is a metal static seal that can withstand high temperature baking. Nominal diameter dimensions include: DN16, 40, 63, 100, 160, 200, 250 Suitable for vacuums up to 10-12 mbar Fla...

+ Continue reading

Difference between cone port and flat port liquid ring vacuum pump

Posted on Thu, 15 Nov 2018 09:27:22 +0000

Among liquid ring vacuum pump, there are conical port and flat port. The typical model for flat port comes to 2BE, 2BV, 2SK, etc. While it’s CL, AT series for conical port. Their major different is the structure and application, here we introduce detail as below: 1) Structure The overall appearan...

+ Continue reading

Vacuum pump system operation

Posted on Thu, 15 Nov 2018 09:11:27 +0000

Pay attention to matters during vacuum unit using Inspection and preparation before starting the vacuum pump system: 1. Check that all bolts are tight; 2. Check if the steering of the motor matches the steering of the pump; 3. Check whether there is lubricating oil (fat) in the bearing chamber. I...

+ Continue reading

oil rotary vane vacuum system in medical center industry application advantages

Posted on Mon, 05 Nov 2018 02:48:49 +0000

Application Advantages of Oil Rotary Vane Vacuum System in Medical Center Industry 1. The oil-type rotary vane vacuum pump is an inevitable trend in the future to replace the water ring vacuum pump in the medical center attracting industry with superior performance advantages, and is also an indu...

+ Continue reading

Turbo molecular pump structure

Posted on Wed, 31 Oct 2018 02:56:26 +0000

The structure and the principle of turbo molecular pump The core components of the molecular pump are rotating blades and stationary blades (Figure 2). The rotating blades rotate at a speed of 1800 to 90,000 rpm, and the speed of the blade ends reaches several hundred m/s, which is close to the a...

+ Continue reading

High temperature problem of vacuum pump

Posted on Fri, 26 Oct 2018 07:36:50 +0000

(1) The motor power and the working current is so large, which causes the vacuum pump have a high temperature. (2) The number of fan blades is small, thus the wind is also small. (3) The fan speed is low, thus the wind pressure and the air volume is small. (4) The bus voltage of the vacuum pump m...

+ Continue reading